Filter sand mill, which is more favored by high viscosity materials, gets rid of the traditional blockage problem and is equipped with Boyi TurboMax independently developed turbine structure.
Provide excellent operational stability, higher equipment flow, improve production efficiency and reduce costs
English User Manual:https://drive.google.com/open?id=1HcFFSdh220gP1FJrMc0MDpKZyoRXl_5T
PM18C Digital Multimeter with T-RMS | ||
Specifications | Range | Accuracy |
DC Voltage | 600mV/6V/60V/600V/1000V | ±(0.5%+3) |
AC Voltage | 6V/60V | ±(0.8%+3) |
600V/1000V | ±(1%+10) | |
DC Current | 60μA/60mA/600MA | ±(0.8%+3) |
20A | ±(1.2%+3) | |
AC Current | 60mA/600MA | ±(1%+3) |
20A | ±(1.5%+3) | |
Resistance | 600/6k/60k/600k/6M | ±(0.8%+3) |
60MΩ | ±(1.2%+30) | |
Capacitance | 6nF | ±(4.0%+30) |
60nF/600nF/6uF/60uF/600uF/6mF | ±(4.0%+5) | |
100mF | ±(5.0%+3) | |
Frequency | 9.999Hz/99.99Hz/999.9Hz/9.999Hz 99.99kHz/999.9kHz/9.999MHz |
±(1.0%+3) |
Duty | 1%~99% | ±(3.0%+5) |
Temperature | ﹣20°C~1000°C/﹣4°F~1832°F | ±(1.0%+3) |
hFE | 0~1000 | ±(1.0%+3) |
Feature | ||
Display | 6000 Counts | |
AVC/ACA TRMS | √ | |
AVC (bandwidth) | 1kHz | |
Continuity | √(sound and LED Alarm) | |
Diode Test | √ | |
Low Battery Indication | √ | |
Live Line Test | √ | |
NCV | √ | |
Back light | √ | |
Data Hold | √ | |
Auto power off | √ | |
General | ||
Power Supply | 1.5V AAA *3 | |
Weight | Approx.331/340g | |
Size | 194*90*56mm | |
Safety Standard/Rating | EN61010-1,EN61010-2-033, EN61326, CAT III 1000V, CAT IV 600V |
The PM18C True RMS Digital Multimeter is a professional-grade tool offering high accuracy and a wide measurement range for voltage, current, resistance, capacitance, frequency, and temperature. Key features include True RMS for precise AC readings, non-contact voltage detection, a 6000 counts display, and a built-in work light. It ensures safety with sound and LED alarms and meets strict safety standards, making it ideal for reliable electrical measurements.