Send Message
Product Range
Seven product lines provide you with ideal testing and analyzing solutions
Quality certification
Passed ISO9001:201 standard quality management system certification; BSCI, CE, FCC, rohs…
Manufacturing process
Exclusive patented technology, ERP management, high level of Quality Control;
Ingenuity concept
Adhering to the spirit if craftsmanship, Peakmeter has always focused on one thing since its establishment;
Guilin Huayi Peakmeter Technology Co., Ltd.
Auto / manual range RCD Loop Tester Digital Multimeter for GFCI  Trip - out Current / Time

Auto / manual range RCD Loop Tester Digital Multimeter for GFCI Trip - out Current / Time

Digital Only
USB2.0 Interface
DC, 45Hz-65Hz
RCD Loop Resistance Tester Digital Multimeter for GFCI Trip-out Current/Time English User Manual:https://drive.google.com/open?id=1sf9LsOu_x0tWCr9Yo0qIbZqYqJNVH2i4 Features of RCD Loop Tester Standard/selective type current measurement lever: 10, 30, 100, 300, 500mA Data stored in host machine can be transmitted to PC via a USB2.0 interface Multiplying power of measurement current: 0.5, 1 and 5 Frequency measurement: DC,45Hz-65Hz 100 groups of test result can be stored Loop Resistance (RL) measurement AC voltage measurement: 0V-440V Power supply: 6x 1.5V AA batteries Contact Voltage Measurement Trip-Out Current measurement Trip-Out Time measurement Storage elevation: 12,000m Low Battery Voltage Alarm Backlight Indication Overheating Alarm Auto/manual range Auto Power Off Specifications Range Accuracy Resolution Tripping-time x1 IΔN300(slow 500ms) ±3ms 0.1ms x5 IΔN40ms(slow 150ms) ±3ms 0.1ms Tripping Current (0.2-1.1)IΔN ±0.1IΔN 0.05IΔN Contact Voltage 0∽99.9V ±(10%+0.2V) 0.01∽0.1V ...
Details
High Performance RCD Loop Tester Multimeter USB Interface High Accuracy

High Performance RCD Loop Tester Multimeter USB Interface High Accuracy

Digital Only
Low Battery Display
0~9.99kΩ
RCD Loop Resistance Tester Multimeter With USB Interface for GFCI English User Manual:https://drive.google.com/open?id=1sf9LsOu_x0tWCr9Yo0qIbZqYqJNVH2i4 Features of RCD Loop Resistance Tester Trip-out current measurement Trip-out time measurement Contact voltage measurement Loop resistance measurement AC voltage measurement :0V ---- 440V Frequency measurement: DC 45Hz----65Hz Specifications Range Accuracy Tripping-time x1 IΔN300(slow 500ms) ±3ms x5 IΔN40ms(slow 150ms) ±3ms Tripping Current (0.2-1.1)IΔN ±0.1IΔN Contact Voltage 0∽99.9V ±(10%+0.2V) Alternating Voltage (UL-N, UL-L, UL-E) 0∽440V ±(3%+3V) Frequency DC, 45∽65Hz ±1Hz Loop Resistance 0.1Ω∽199.9Ω ±(10%+0.2d) 200∽1999Ω ±(10%+0.2d) 2000∽9.99kΩ ±(10%+0.2d) RL Current test 0.5 IΔN ±(10%+10d) Multiplying Power of Measuring Current x0.5, x1, x5 Current Level (IΔN) 10mA,30mA,100mA,300mA,500mA Trigger Phase Angle 0° or 180° Feature Data Logging and Recall 1000Groups Auto Power Off √ Display Back Light √ USB 2.0Interface √ Low Battery ...
Details
Auto Power Off Digital RCD Loop Tester Trip - Out Current / Time For GFCI

Auto Power Off Digital RCD Loop Tester Trip - Out Current / Time For GFCI

Digital Only
USB2.0 Interface
DC, 45Hz-65Hz
Digital RCD Loop Resistance Tester , Trip - Out Current / Time For GFCI Features of Digital RCD Loop Tester Trip-Out Current measurement Trip-Out Time measurement Contact Voltage Measurement Loop Resistance (RL) measurement AC voltage measurement: 0V-440V Frequency measurement: DC,45Hz-65Hz Multiplying power of measurement current: 0.5, 1 and 5 Standard/selective type current measurement lever: 10, 30, 100, 300, 500mA 100 groups of test result can be stored Data stored in host machine can be transmitted to PC via a USB2.0 interface Backlight Indication Auto Power Off Overheating Alarm Low Battery Voltage Alarm Auto/manual range Power supply: 6x 1.5V AA batteries Storage elevation: 12,000m Specifications Range Accuracy Tripping-time x1 IΔN300(slow 500ms) ±3ms x5 IΔN40ms(slow 150ms) ±3ms Tripping Current (0.2-1.1)IΔN ±0.1IΔN Contact Voltage 0∽99.9V ±(10%+0.2V) Alternating Voltage (UL-N, UL-L, UL-E) 0∽440V ±(3%+3V) Frequency DC, 45∽65Hz ±1Hz Loop Resistance 0.1Ω∽199.9Ω ±(10%+0.2d) 200...
Details
100 Groups Digital RCD Tester Data Logging , GFCI Earth Loop Impedance Meter

100 Groups Digital RCD Tester Data Logging , GFCI Earth Loop Impedance Meter

0.1~2000ohm
DC, 45Hz-65Hz
0~9.99kΩ
100 Groups Data Logging RCD Loop Resistance Tester With USB Interface For GFCI English User Manual:https://drive.google.com/open?id=1sf9LsOu_x0tWCr9Yo0qIbZqYqJNVH2i4 Features of RCD Loop Tester Trip-out current measurement Trip-out time measurement Contact voltage measurement Loop resistance measurement AV voltage measurement:0V-400V Frequency measurement: DC 45Hz-65Hz Specifications Range Accuracy Tripping-time x1 IΔN300(slow 500ms) ±3ms x5 IΔN40ms(slow 150ms) ±3ms Tripping Current (0.2-1.1)IΔN ±0.1IΔN Contact Voltage 0∽99.9V ±(10%+0.2V) Alternating Voltage (UL-N, UL-L, UL-E) 0∽440V ±(3%+3V) Frequency DC, 45∽65Hz ±1Hz Loop Resistance 0.1Ω∽199.9Ω ±(10%+0.2d) 200∽1999Ω ±(10%+0.2d) 2000∽9.99kΩ ±(10%+0.2d) RL Current test 0.5 IΔN ±(10%+10d) Multiplying Power of Measuring Current x0.5, x1, x5 Current Level (IΔN) 10mA,30mA,100mA,300mA,500mA Trigger Phase Angle 0° or 180° Feature Data Logging and Recall 1000Groups Auto Power Off √ Display Back Light √ USB 2.0Interface √ Low Battery Display √ ...
Details
Digital Resistance RCD Loop Tester Multifunctional High Reliability And Safety

Digital Resistance RCD Loop Tester Multifunctional High Reliability And Safety

Digital Only
USB2.0 Interface
DC, 45Hz-65Hz
Digital RCD Loop Resistance Tester Complys With IEC/EN 61010-1 1000V CAT II, 600V CAT III English User Manual:https://drive.google.com/open?id=1sf9LsOu_x0tWCr9Yo0qIbZqYqJNVH2i4 Features of RCD Loop Resistance Tester Trip-out current measurement Trip-out time measurement Contact voltage measurement Loop resistance measurement AC voltage measurement :0V ---- 440V Frequency measurement: DC 45Hz----65Hz Specifications Range Accuracy Tripping-time x1 IΔN300(slow 500ms) ±3ms x5 IΔN40ms(slow 150ms) ±3ms Tripping Current (0.2-1.1)IΔN ±0.1IΔN Contact Voltage 0∽99.9V ±(10%+0.2V) Alternating Voltage (UL-N, UL-L, UL-E) 0∽440V ±(3%+3V) Frequency DC, 45∽65Hz ±1Hz Loop Resistance 0.1Ω∽199.9Ω ±(10%+0.2d) 200∽1999Ω ±(10%+0.2d) 2000∽9.99kΩ ±(10%+0.2d) RL Current test 0.5 IΔN ±(10%+10d) Multiplying Power of Measuring Current x0.5, x1, x5 Current Level (IΔN) 10mA,30mA,100mA,300mA,500mA Trigger Phase Angle 0° or 180° Feature Data Logging and Recall 1000Groups Auto Power Off √ Display Back Light √ USB 2...
Details
USB Interface RCD Loop Tester Multimeter Stable Performance For GFCI

USB Interface RCD Loop Tester Multimeter Stable Performance For GFCI

USB 2.0 Interface
0.1~9.99kΩ
0~99.9V
RCD Loop Resistance Tester Multimeter With USB Interface For GFCI English User Manual:https://drive.google.com/open?id=1sf9LsOu_x0tWCr9Yo0qIbZqYqJNVH2i4 Features of RCD Loop Resistance Tester Trip-out current measurement Trip-out time measurement Contact voltage measurement Loop resistance measurement AC voltage measurement :0V ---- 440V Frequency measurement:DC 45Hz----65Hz Specifications Range Accuracy Tripping-time x1 IΔN300(slow 500ms) ±3ms x5 IΔN40ms(slow 150ms) ±3ms Tripping Current (0.2-1.1)IΔN ±0.1IΔN Contact Voltage 0∽99.9V ±(10%+0.2V) Alternating Voltage (UL-N, UL-L, UL-E) 0∽440V ±(3%+3V) Frequency DC, 45∽65Hz ±1Hz Loop Resistance 0.1Ω∽199.9Ω ±(10%+0.2d) 200∽1999Ω ±(10%+0.2d) 2000∽9.99kΩ ±(10%+0.2d) RL Current test 0.5 IΔN ±(10%+10d) Multiplying Power of Measuring Current x0.5, x1, x5 Current Level (IΔN) 10mA,30mA,100mA,300mA,500mA Trigger Phase Angle 0° or 180° Feature Data Logging and Recall 1000Groups Auto Power Off √ Display Back Light √ USB 2.0Interface √ Low Battery ...
Details
1
Guilin Huayi Peakmeter Technology Co., Ltd.
Openness · Cooperation · Shared Benefits · Win-win Outcomes
Contact Us

Please check your E-mail!

Your message must be between 20-3,000 characters!